specialoreo.blogg.se

Zona lumbar
Zona lumbar






zona lumbar

The group of MIT researchers believe that these implantable fibers could allow scientists to stimulate specific targets in the brain to monitor electrical activity 1,2. These novel optical fibers facilitating the simultaneous electrical recording and optical stimulation could open up new possibilities in neuroscience, especially in avenues benefitting the monitoring and recovery of patients with spinal cord injuries 1,2. The simultaneous recording of optically-evoked potentials and the optical control of hind limb muscles suggests that these fiber may potentially be used in monitoring and controlling neural activity to promote recovery following spinal injury 2. To test the functionality of this probe in animal models, the neural probe was implanted into the spinal cord of mice and the mechanical, optical and electrical properties allowed for acute recordings of spontaneous neural activity through sensory-evoked potentials 2. Impedance measurements over five extension and release cycles of the stretchable neural probes showed that these fibers are stretchable and bendable. Furthermore, impedance values of similar orders of magnitude were recorded in fiber probe measurements ranging from 1 cm to 10 cm, suggesting the scalability of this fabrication approach to larger animals 2. Transmission electron microscopy images revealed that the resistivity of AgNW mesh is directly proportional to the concentration of dip-coated solutions at concentrations above 6 mg/ml 2. The PC/COC/AgNW probes showed good flexibility with a maintained transmission under extreme deformations that were carried out by bending the fiber to 90° and 180° 2. The results showed that the nanofibers with then COC cladding (PC/COC/AgNW) showed an increased transmission at a wavelength (λ) of 473 nm as compared to the nanofibers without the COC cladding (PC/AgNW) at the same wavelength 2. As a result of this design, these hybrid probes maintained low optical transmission losses in visible range showed promise in extracellular recording under strains exceeding mammalian spinal cords.

zona lumbar

To minimize direct contact of the AgNW with tissues, and to also prevent surface oxidation and mechanical degradation, the entire structure is further encapsulated in polydimethyl siloxane (PDMS) 2. Dip coating required the use of different concentrations of isopropanol (IPA) solutions after treating the fibers with oxygen plasma to improve adhesion and enhance the uniformity of AgNW mesh layers 2.

zona lumbar

To facilitate an accurate neural recording, a 1 micrometer (mm) thick conductive layer of AgNWs with a diameter of 70 nm and a length 40 nm was deposited over the COC cladding by a process called dip coating. Polycarbonate (PC) was used as the core of the optical fiber, and cyclic olefin copolymer (COC) was used for cladding of the optical fiber 2.

zona lumbar

To fabricate a probe that is suitable for both optical neuromodulation and electrophysiological recording, Anikeeva’s team used thermal drawing, a process involving heating, drawing/stretching under stress and cooling a material, to produce a flexible optical fiber. These models could therefore serve as an indispensable tool for the discovery of neural pathways that are important for recovery following spinal injury 2. The optogenetic modulation capabilities of genetically identifiable neural populations in the rodent models have been successfully used in neuroscience. The low elastic modulus of 0.25 to 0.3 megaPascals (MPa) of the spinal cord requires these engineered probes to be both elastic and bendable, similar to the nature of the spinal cord, in order to withstand repeated strains, while still being able to record electrophysiological activity during spinal cord deformations. Diagnosing and treating such patients requires optoelectronic devices to modulate and record the electrophysiological activity of specific neurons that are affected 2. Spinal cord injuries in multiple trauma patients are frequently associated with the loss of organ function and/or the loss of voluntary limb control 2. The team used elastic polymers, coated with micrometer-thick meshes of conductive silver nanowires (AgNWs), which allowed these probes to be both stretchable and electrically conductive 1. Polina Anikeeva’s team developed a stretchable and flexible probe that can be used in developing tools that are useful for monitoring and manipulating neural dynamics in the spinal cord. A research team from the Massachusetts Institute of Technology’s (MIT) Department of Materials Science and Engineering has recently developed nanowire-coated fibers for optoelectronic probing of spinal cord circuits.








Zona lumbar